Voltage drop--
Voltage drop--
Estimate voltage drop for an extension cord from amps, length, voltage, and wire gauge.
Voltage drop--
Voltage drop--
Enter the measurements or usage numbers you know, then use the result as a planning estimate. The defaults are realistic starting points, but the best result comes from replacing them with your actual product, property, trip, or equipment numbers.
Use it as a planning estimate, then verify against product coverage, local requirements, and the conditions on your property or trip.
Real projects and outdoor conditions rarely match the perfect math. A small reserve helps cover waste, uneven ground, spills, weather, and user input error.
The extension cord voltage drop calculator estimates how much voltage is lost through a cord based on amps, length, wire gauge, and supply voltage. It helps screen long cord runs for tools, generators, pumps, chargers, and temporary work setups.
Voltage drop is based on current, conductor resistance, and length. The calculator estimates lost volts and percent drop so you can compare the setup with common planning limits and equipment requirements.
A low drop supports better equipment performance, but voltage drop is only one safety check. Cord amp rating, jacket type, grounding, GFCI protection, wet-location rating, and equipment instructions still matter.
Example: a 12 amp tool on a 100 foot, 14 gauge cord may show a larger voltage drop than the same tool on a shorter 12 gauge cord. If the percent drop is high, the tool may run hot, start poorly, or trip protection. A shorter cord, heavier gauge cord, lower load, or different power source may be needed.
Extension-cord and voltage-drop estimates are not professional electrical advice. Follow cord labels, manufacturer specs, OSHA or job-site rules where applicable, GFCI requirements, local electrical code, and consult a qualified electrician for temporary power, generator connections, or permanent wiring.
Many planning references aim for a low percentage, but equipment manuals and electrical guidance should control final decisions.
Yes, for the same load and wire gauge, increasing length increases resistance and voltage drop.
Yes. A lower gauge number usually means a thicker conductor and less voltage drop for the same length and load.
No. Permanent wiring must follow electrical code and should be designed or reviewed by a qualified professional.
A loaded coiled cord can retain heat. Follow the cord label and manufacturer instructions for safe use.
Before using a long cord, check the printed cord label for gauge, amp rating, grounding, outdoor rating, and temperature limits. The calculator can estimate voltage drop, but it cannot confirm that a damaged cord, undersized outlet, wet-location setup, or overloaded power strip is safe. If the equipment has a motor, test the setup under supervision and stop if the cord, plug, or tool becomes warm, smells hot, or trips protection.
For generator use, keep the generator outside and away from doors, windows, vents, garages, and crawlspaces because carbon monoxide can be deadly. Use cords and connections that match the generator manual, and get qualified electrical guidance for anything tied into building wiring.